228

Chapter 8 Working with Test Sequences

Note: When you send the .txt file to the generator, the file will be automatically
converted to an XML file.

3. Set the sequence path to the sequence directory on the generator’s flash memory or

the PC card. For example, to set the path to the generator’s flash memory, enter the
following command:

SEQP

/tffs0/Library/Sequence

To set the sequence path to the PC card, enter the following command:

SEQP

/card0/Library/Sequence

4. Establish a session with the generator using either HyperTerminal over a serial

connection or Telnet over an Ethernet LAN. See

Establishing a terminal session with

the generator

” on page 31 or

Establishing a Telnet session with the generator

” on page

34.

5. Transfer the text file to the generator. For example, to transfer the file using

HyperTerminal, do the following:

a. On the

Transfer menu, click Send Text File. The Send Text File dialog box

appears.

b. Select the text file you want to send, and then click

Open. HyperTerminal displays

the commands as they are sent.

c. Press

Enter once to ensure that the last command is sent.

Advertising
This manual is related to the following products: