881/882 Video Test Generator User Guide (Rev A.22)

251

6. Press the

Source key and choose the format you want to use.

Any built-in formats may be used for this test. However, we recommend using several
formats spread over a wide range of frequencies. For example, the Test150 format tests
at the maximum supported pixel frequency for HDMI. The DMT0660 format can be
used to test at a very low frequency (25.175 MHz).

Note: The list of formats that appears when you press the Source key may be a filtered
or abbreviated list. Formats not suitable for the selected interface type will not appear
by default on the

Source list. You may have to enable the Test format library. If the Test

format library is disabled you will not see the TEST150 format. To enable the Test
format library, see

Format catalogs

” on page 193.

Use the following formats to test HDMI over a range of frequencies:

7. Press the

Tools key. The Tools menu appears on the generator’s display as shown

below.

8. Choose the

Analyzer item by pressing the adjacent soft key. The Analyzer menu

appears on the generator’s display as shown below.

9. Choose the

CableTest item by pressing the adjacent soft key. The CableTest menu

appears as shown below.

10. Choose the

Settings item by pressing the adjacent soft key or press the Settings key

to select the analysis duration in the number of sequences.

Format

Pixel rate (MHz)

TEST150

150.000

1080p60

148.500

720p60

74.250

DMT0660

25.175

System
Sequence
Probe
AFC

Analyzer

Reports

ImgShift

Timing
CableTest

PIX-ERR

PRN-ERR

*

ReadRGB

Start
Settings

Exit !

!

Advertising
This manual is related to the following products:

882