Quantum Data 881 User Manual

Page 561

Advertising
background image

881/882 Video Test Generator User Guide

(Rev A.22)

543

2. Configure the generator/analyzer to emulate the desired EDID using the procedures in

Testing EDID handling of source device

” on page 524 or

Emulating an EDID

” on page

564.

If you need to create a custom EDID, use the EDID Editor utility described in

Creating

a new EDID

” on page 554.

3. Connect an HDMI-to-HDMI cable between the HDMI OUT connector on the source

device under test and the first HDMI connector on the TPA-DDC-RR Test Point Adapter.

4. Connect an HDMI-to-HDMI cable between the HDMI IN connector on the 882

generator/analyzer and the second HDMI connector on the TPA-DDC-RR Test Point
Adapter.

The figure below shows the TPA-DDC-RR device.

The following diagram illustrates the test setup.

5. Set the capacitance to the desired value by flipping the toggle switch to the “1” or “2”

position.

DDC Dynamic Elecrical Test Fixture

Model TPA-DDC-RR

HDMI

SDA

LOAD

1 = 1400pf

2 = 750pf

+ -

HDMI

1

2

SDA

+ -

Device under

test (source)

882CA EDID

Emulator

Host PC with

Auxiliary Channel Analyzer

DDC Dynamic

Electrical Test Fixture

HDMI

HDMI

HDMI TX

HDMI RX

HDMI RX

Advertising
This manual is related to the following products:

882