354

Chapter 11 CEC Interactive Troubleshooting Environment (ITE)

Overview

This chapter provides procedures for testing HDMI source and sink devices for CEC
functionality using the Interactive Troubleshooting Environment (ITE). When testing
HDMI-CEC source devices the generator (analyzer) will emulate a CEC sink device such
as an HDTV. When testing HDMI-CEC sink devices, the 882 generator will emulate a CEC
source device such as a set top box (STB) unless you instruct it not to.

Note: The CEC ITE is an option available on generators with release 2.2.2 or higher. You
must have the ITE option on your generator to use the ITE features. To determine if your
generator has the the ITE option installed,
view the GenStats image and check the information under Options. Refer to

Viewing

generator configuration information

” on page 129.

The CEC ITE provides a set of commands to accomplish the following:

Configure an HDMI port on the 882C(A) to emulate an HDMI source of sink

Send and query messages on the CEC bus

Query messages on the CEC bus

Monitor the CEC bus for timing errors