881/882 Video Test Generator User Guide (Rev A.22)

373

CEC1:CECT:0BIT 1.5 2.25

//sets the low period of a zero bit to 1.5

milliseconds and the total bit time to
2.25 milliseconds

3. Enter the following command to modify the timing of the start bit in a message.

CEC1:CECT:SBIT 3.7 4.5

//sets the low period of a start bit to 3.7

milliseconds and the total bit time to
4.5 milliseconds

To test the bit timing through the CEC Controller:

1. Access the CEC Controller using the procedures in

To run the CEC Controller:

” on

page 370.

The table below describes the fields of the

Control Timing portion of the CEC

Controller dialog box.

2. Select the high period or low period of the start bit, logical 0 bit or logical 1 bit by

selecting the associated radio button.

Note that you can apply multiple settings for each command. For example you could
change the timing for both the high and low periods of the start, 0 bit and 1 bits
simultaneously. You have to reset each timing change.

Setting

Function

Start bit low period

sets the time duration of the start bit low period

Start bit total bit period

sets the time duration of the start bit total period
which enables you to set the high period

1 bit low period

sets the time duration of the 1 bit low period

1 bit total period

sets the time duration of the start bit total period
which enables you to set the high period

0 bit low period

sets the time duration of the 0 bit low period

0 bit total period

sets the time duration of the 0 bit total period
which enables you to set the high period

Advertising
This manual is related to the following products:

882