Bl-1019, Bl-1020, Bl-1021 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 124

108
Network OS Message Reference
53-1003227-01
BL-1019
8
BL-1019
Message
<Slot string>, retry <Retry Number>, internal port retry initialization, <List of
internal ports retrying initialization>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified slot had internal ports that are not online. Initiated a retry on ports that failed
to go online.
Recommended
Action
No action is required.
BL-1020
Message
Switch timed out initializing the chips.
Message Type
LOG | FFDC
Severity
CRITICAL
Probable Cause
Indicates that the switch has failed to initialize the application-specific integrated circuit (ASIC) chips.
Recommended
Action
Reload power cycle the switch.
Execute the diag systemverification command to verify that the switch does not have hardware
problems.
Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled.
If the message persists, replace the switch.
BL-1021
Message
Retry <Retry Number>, internal port retry initialization, <List of internal ports
retrying initialization>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the switch had internal ports that are not online. Initiated a retry on ports that failed to go
online.
Recommended
Action
No action is required.