BL-1019

8

BL-1019

Message

<Slot string>, retry <Retry Number>, internal port retry initialization, <List of

internal ports retrying initialization>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the specified slot had internal ports that are not online. Initiated a retry on ports that failed
to go online.

Recommended

Action

No action is required.

BL-1020

Message

Switch timed out initializing the chips.

Message Type

LOG | FFDC

Severity

CRITICAL

Probable Cause

Indicates that the switch has failed to initialize the application-specific integrated circuit (ASIC) chips.

Recommended

Action

Reload power cycle the switch.

Execute the diag systemverification command to verify that the switch does not have hardware
problems.

Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled.

If the message persists, replace the switch.

BL-1021

Message

Retry <Retry Number>, internal port retry initialization, <List of internal ports

retrying initialization>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the switch had internal ports that are not online. Initiated a retry on ports that failed to go
online.

Recommended

Action

No action is required.