Rtwr messages, Rtwr-1001, Rtwr-1002 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 377

Network OS Message Reference
361
53-1003227-01
RTWR-1001
8
RTWR Messages
RTWR-1001
Message
RTWR <routine: error message> 0x<detail 1>, 0x<detail 2>, 0x<detail 3>, 0x<detail
4>, 0x<detail 5>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that an error occurred in Reliable Transport Write and Read (RTWR) due to one of the following
reasons:
•
The system ran out of memory.
•
The domain may be unreachable.
•
The frame transmission failed.
•
An internal error or failure occurred.
The message contains the name of the routine that has an error and other error-specific information.
Refer to values in details 1 through 5 for more information.
Recommended
Action
Execute the reload command to restart the switch.
RTWR-1002
Message
RTWR <error message: Maximum retries exhausted> 0x<port>, 0x<RBridge>, 0x<retry
count>, 0x<status>, 0x<process ID>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that Reliable Transport Write and Read (RTWR) has exhausted the maximum number of retries
for sending data to the specified RBridge.
Recommended
Action
Execute the show fabric all command to verify that the specified RBridge ID is online.
If the switch with the specified RBridge ID is offline, enable the switch using the chassis enable
command.
If the message persists, execute the copy support command and contact your switch service provider.