Ssmd-1004, Ssmd-1005, Ssmd-1006 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 421

Network OS Message Reference
405
53-1003227-01
SSMD-1004
8
SSMD-1004
Message
Failed to unlock semaphore mutex: (<function name>).
Message Type
DCE
Severity
ERROR
Probable Cause
Indicates that the specified function has failed to unlock the mutex (semaphore).
Recommended
Action
Reload or power cycle the switch.
SSMD-1005
Message
SSM startup failed.
Message Type
DCE
Severity
ERROR
Probable Cause
Indicates that the Data Center Ethernet (DCE) System Services Manager (SSM) has encountered an
unexpected severe error during basic startup and initialization.
Recommended
Action
Reload or power cycle the switch.
If the problem persists, download a new firmware version using the firmware download command.
SSMD-1006
Message
SSM ASIC downlaod buffer overflow (size <required buffer size> > max <max buffer
size>) in function <function name>.
Message Type
DCE
Severity
ERROR
Probable Cause
Indicates that the Data Center Ethernet (DCE) System Services Manager (SSM) has encountered an
unexpected severe error when fill in the I/O control (IOCTL) structure.
Recommended
Action
Reload or power cycle the switch.
If the problem persists, download a new firmware version using the firmware download command.