Eanv messages, Eanv-1001, Eanv-1002 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 164: Eanv-1003

148
Network OS Message Reference
53-1003227-01
EANV-1001
8
EANV Messages
EANV-1001
Message
Port <port number> port fault. Change the SFP transceiver or check the cable.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.
Recommended
Action
Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable if
necessary.
EANV-1002
Message
Port <port number> chip faulted due to an internal error.
Message Type
LOG | FFDC
Severity
ERROR
Probable Cause
Indicates an internal error. All the ports on this chip will be disabled.
Recommended
Action
Reload the system at the next maintenance window.
EANV-1003
Message
C<chip index>: HW ASIC Chip error. Type = 0x<chip error type>, Error = <chip error
string>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.
Recommended
Action
Reload the system at the next maintenance window.