Ag-1029, Ag-1030, Ag-1031 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 98: Ag-1032

82
Network OS Message Reference
53-1003227-01
AG-1029
8
AG-1029
Message
FC ports going to different fabrics. Disabling ports going to different fabric.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a misconfiguration.
Recommended
Action
Connect all ports in the switch to the same FC fabric.
AG-1030
Message
N-Port (ID: <port>) has been determined to be unreliable.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the port goes online and offline often and therefore the port is marked as unreliable.
Recommended
Action
No action is required. The port will automatically be marked as reliable after a certain interval of time if
the port toggling remains within the threshold limit.
AG-1031
Message
Loop Detected for device with Port WWN <port_name> connected to port <port>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a routing loop is detected for the device connected to the specified port.
Recommended
Action
Check the device configuration.
AG-1032
Message
N-Port (ID: <port>) has recovered from an unreliable state.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the port state has been stable for the last five minutes.