Bl-1022, Bl-1023, Bl-1024 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 125

Network OS Message Reference
109
53-1003227-01
BL-1022
8
BL-1022
Message
Init Failed: Switch DISABLED because internal ports were not ONLINE, <list of
internal port number not ONLINE>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the switch initiation failed because one or more of the internal ports were not online. The
switch is faulted.
Recommended
Action
Reload or power cycle the switch.
Execute the diag systemverification command to verify that the switch does not have hardware
problems.
Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled.
Additional fault messages precede and follow this error providing more information. Refer to other error
messages for recommended action.
If the message persists, replace the switch.
BL-1023
Message
Interface module in <slot string> was reset before initialization completed. As a
result the interface module is faulted.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the interface module was reset before the initialization completed.
Recommended
Action
Reload or power cycle the interface module using the power-off and power-on commands. If the
message persists, replace the interface module.
BL-1024
Message
All ports on the interface module in <slot string> will be reset as part of the
firmware upgrade.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a recent firmware upgrade caused the interface module firmware to be upgraded and
resulted in a cold upgrade. As part of the upgrade, all data path elements were reset.
Recommended
Action
No action is required.