Fvcs messages, Fvcs-1003, Fvcs-1004 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 215: Fvcs-2001

Network OS Message Reference
199
53-1003227-01
FVCS-1003
8
FVCS Messages
FVCS-1003
Message
Possible vLAG Split Detected vLAG - ifindex (<vLAG ifindex>), split RBridge(<split
RBridge >).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the RBridge has left the cluster.
Recommended
Action
If the RBridge was not disabled on purpose, check if it is still connected to the cluster using the show
fabric isl command.
FVCS-1004
Message
HA Sync Failure- THA API call Failed and Retries timed out rc (<API RC>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the Transparent High Availability (THA) library state synchronization attempt has failed.
Recommended
Action
No action is required. If the message persists, execute the copy support command and contact your
switch service provider.
FVCS-2001
Message
FCS Primary Update Send attempt Failed - reason (<Failure Reason>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the remote switch has rejected the update. Refer to the failure reason for more details.
Recommended
Action
Execute the show fabric isl command to check the cluster connection status.
If the message persists, execute the copy support command and contact your switch service provider.