Bl-1046, Bl-1047, Bl-1049 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 130

114
Network OS Message Reference
53-1003227-01
BL-1046
8
BL-1046
Message
<Slot number of interface module that has the SFP> error on SFP in Slot <Port
number into which the SFP is inserted>/Port <The type of error 'checksum' or 'data
access' for general problems accessing the i2c accessible data> (<A detailed error
code>). Reseat or replace the SFP.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that checksum in an area on the small form-factor pluggable (SFP) transceiver does not match
with the computed value or there is problem accessing the data.
Recommended
Action
Reseat the SFP transceiver. If the problem persists, replace the SFP transceiver.
BL-1047
Message
Buffer optimized mode is turned <buffer optimized mode> for slot <slot number>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the buffer optimized mode is changed for the specified slot.
Recommended
Action
No action is required.
BL-1049
Message
Incompatibility with an active 12x40G LC detected, faulting the interface module
in <slot string>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that this line card (LC) is incompatible with one or more existing 12x40G LCs.
Recommended
Action
Power cycle all active 12X40G LCs and then power cycle the interface module using the power-off and
power-on commands. Then power on all 12X40G LCs. After completing these steps, all LCs can
interoperate with one another.