Bll messages, Bll-1000 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 131

Advertising
background image

Network OS Message Reference

115

53-1003227-01

BLL-1000

8

BLL Messages

BLL-1000

Message

ASIC driver detected <slot string> port <port number> as faulty (reason: <reason

code>).

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that an interface module regulation problem was reported on the specified slot. The interface
module is faulted.

The reason codes are as follows:

•

1 = Available buffer overflow

•

2 = Backend port buffer timeout

•

3 = Backend port got shut down

•

4 = Embedded port buffer timeout

•

5 = Excessive busy mini buffer

•

6 = Excessive RCC VC on E_Port

•

7 = Excessive RCC VC on FL_Port

•

8 = Fail detection buffer tag error

•

9 = Fail detection TX parity error

•

10 = EPI CMEM interrupt error

•

11 = Checkpoint Middleware Interface (CMI) interrupt error

•

12 = Interrupt overrun

•

13 = FDET interrupt

•

14 = Interrupt suspended

•

15 = Filter LISTD error

•

16 = Unknown filter LIST error

•

17 = Wait for LPC open state

•

18 = Wait for Old port state

•

19 = Wait for Open init state

•

20 = TX parity error

•

21 = RAM parity error

•

22 = Built in Self Repair (BISR) or RAMINIT error

Recommended

Action

Make sure the interface module is seated correctly. If the interface module is seated correctly, reload or
power cycle the interface module using the power-off and power-on commands.

Execute the diag systemverification command to verify that the interface module does not have
hardware problems.

If the message persists, replace the interface module.