Fabs-1014, Fabs-1015 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 196

180
Network OS Message Reference
53-1003227-01
FABS-1014
8
FABS-1014
Message
<Method name>[<Method tag number>]:Unknown FRU type 0x<FRU Object type>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that an unrecognized type of field-replaceable unit (FRU) has been discovered in the system.
This error can be caused by one of the following reasons: an incorrect FRU header, inability to read the
FRU header, or the FRU may not be supported by this platform or Network OS version.
Recommended
Action
Verify that the FRU is valid for use in this system and this version of Network OS.
Reseat the FRU.
If this is a valid FRU and reseating does not solve the problem, replace the FRU.
FABS-1015
Message
<Method name>[<Method tag number>]:Request to enable FRU type 0x<FRU Object type>,
unit <Unit number> failed. err code <Error code>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified field-replaceable unit (FRU) could not be enabled. This is usually an internal
Network OS problem.
Recommended
Action
Remove and reinsert the FRU.
Reload or power cycle the management module or switch.
If the message persists, execute the firmware download command to update the firmware.