Fw-1051, Fw-1052, Fw-1297 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 230

214
Network OS Message Reference
53-1003227-01
FW-1051
8
FW-1051
Message
<Label>, is above high boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) transceiver voltage has risen above the
high boundary. High voltages indicate possible hardware failures.
Recommended
Action
Frequent voltage fluctuations are an indication that the SFP transceiver is deteriorating. Replace the SFP
transceiver.
FW-1052
Message
<Label>, is between high and low boundaries(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) transceiver voltage has changed from a
value outside of the acceptable range to a value within the acceptable range.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.
FW-1297
Message
<Label>, is below low boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the number of Telnet violations has fallen below the low boundary. Telnet violations indicate
that a Telnet connection request has been received from an unauthorized IP address. The
TELNET_POLICY contains a list of IP addresses that are authorized to establish Telnet connections to
switches in the fabric.
Recommended
Action
No action is required.