EM-1008
8
EM-1008
Message
Unit in <Slot number or Switch> with ID <FRU Id> is faulted, it is incompatible
with the <type of incompatibility> configuration, check firmware version as a
possible cause.
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that an interface module inserted in the specified slot or the switch (for compact switches) is not
compatible with the platform configuration (includes the firmware version). The interface module is
faulted.
Recommended
Action
If the interface module is not compatible, upgrade the firmware or replace the interface module and make
sure the replacement interface module is compatible with your management module type and firmware.
EM-1009
Message
<FRU Id> powered down unexpectedly.
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that the environmental monitor (EM) received an unexpected power-down notification from the
specified field-replaceable unit (FRU). This may indicate a hardware malfunction in the FRU.
Recommended
Action
Reseat the FRU. If the problem persists, replace the FRU.
EM-1010
Message
Received unexpected power down for <FRU Id> but <FRU Id> still has power.
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that the environmental monitor (EM) received an unexpected power-down notification from the
specified field-replaceable unit (FRU). However, the specified FRU still appears to be powered up after 4
seconds.
Recommended
Action
Reseat the interface module. If the problem persists, replace the interface module.