Em-1045, Em-1046, Em-1047 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 177

Network OS Message Reference
161
53-1003227-01
EM-1045
8
EM-1045
Message
<FRU Id> is being powered <new state>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that an automatic power adjustment is being made because of the (predicted) failure of a power
supply or the insertion or removal of a port interface module.
The new state can be one of the following:
•
On - A port interface module is being powered on because more power is available (either a power
supply was inserted or a port interface module was removed or powered down).
•
Off - A port interface module has been powered down because of a (predicted) failure of the power
supply.
•
Down - A newly inserted port interface module was not powered on because there was not enough
power available.
Recommended
Action
Refer to the Hardware Reference Manual of your switch for the number of power supplies required for
redundancy.
EM-1046
Message
Error status received for interface module ID <id value> for <FRU Id>, <interface
module incompatibility type: platform>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified interface module is incompatible.
Recommended
Action
If the interface module ID listed is incorrect, the field-replaceable unit (FRU) header for the interface
module is corrupted and the interface module must be replaced.
If the error is due to platform, the interface module ID listed is not supported for that platform
(management module) type. Remove the interface module from the chassis.
EM-1047
Message
MM in <FRU Id> is booting up.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the firmware in the specified management module is now in the boot process. This
message usually follows the EM-1033 message. The new standby management module is in the process
of reloading and has turned off the MM_ERR signal.