Trce messages, Trce-1002, Trce-1003 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 446: Trce-1005

430
Network OS Message Reference
53-1003227-01
TRCE-1002
8
TRCE Messages
TRCE-1002
Message
Trace dump<optional slot indicating on which slot the dump occurs> automatically
transferred to address ' <FTP target designated by user> '.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a trace dump has occurred on the switch or the specified slot, and the trace dump files
were automatically transferred from the switch to the specified FTP server.
Recommended
Action
No action is required.
TRCE-1003
Message
Trace dump<optional slot indicating on which slot the dump occurs> was not
transferred due to FTP error.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that a trace dump has occurred on the switch or the specified slot, but the trace dump files were
not automatically transferred from the switch due to reasons such as an FTP error, wrong FTP address,
FTP site is down, and network is down.
Recommended
Action
If the message persists, execute the copy support command and contact your switch service provider.
TRCE-1005
Message
FTP Connectivity Test failed due to error.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the connectivity test to the FTP host failed because of reasons such as a wrong FTP
address, FTP site is down, or network is down.
Recommended
Action
Execute the copy support command and contact your switch service provider.