Hasm-1132, Hasm-1200, Hasm-1201 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 260

244
Network OS Message Reference
53-1003227-01
HASM-1132
8
HASM-1132
Message
Reset the Ethernet PHY for slot <slot/partition> (<reset return code>>) on
standby.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that there was no Ethernet connection between the standby management module and the
specified line card (LC). The standby management module attempted to recover the connection by
resetting the PHY in the LC.
Recommended
Action
Execute the copy support command and contact your switch service provider.
HASM-1200
Message
Detected termination of process <Software component>:<Software component Process
ID>.
Message Type
FFDC | LOG
Severity
WARNING
Probable Cause
Indicates that a process on the switch has ended unexpectedly.
Recommended
Action
Copy the warning message along with any core file information and contact your switch service provider.
HASM-1201
Message
<Software component>:<Software component Process ID> failed to refresh (<Current
time>:<Refresh time>, kill-<signal killed>).
Message Type
FFDC | LOG
Severity
WARNING
Probable Cause
Indicates that one of the daemons is found to be unresponsive. An abort signal is sent.
Recommended
Action
Copy the warning message along with any core file information and contact your switch service provider.