Ag-1012, Ag-1015, Ag-1017 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 96

80
Network OS Message Reference
53-1003227-01
AG-1012
8
AG-1012
Message
Sending logout (LOGO) request failed on N_Port <port>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that there was a failure sending an N_Port logout request from the Access Gateway to the
fabric switch.
Recommended
Action
Check the configuration of the fabric switch connected to the Access Gateway.
If the message persists, execute the copy support command and contact your switch service provider.
AG-1015
Message
Unable to find online N_Ports to connect to the fabric.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that no other N_Port is configured or all N_Ports are currently offline.
Recommended
Action
Check whether any other N_Port is configured.
If the message persists, execute the copy support command and contact your switch service provider.
AG-1017
Message
No N_Port(s) are currently Online.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that no N_Ports are currently configured in the system or all configured N_Ports have failed to
come online.
Recommended
Action
Run the show fabric islports command to display the status of all ports in the system and run show
running-config interface FibreChannel to display a list of ports currently configured as N_Ports.