Plat messages, Plat-1000, Plat-1001 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 355: Plat-1002

Advertising
background image

Network OS Message Reference

339

53-1003227-01

PLAT-1000

8

PLAT Messages

PLAT-1000

Message

<Function name> <Error string>.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that nonrecoverable peripheral component interconnect (PCI) errors have been detected.

Recommended

Action

The system will be faulted and may reload automatically.

If the system does not reload, execute the reload command.

Execute the copy support command and contact your switch service provider.

PLAT-1001

Message

MM<Identifies which MM (1 or 2) is doing the reset> resetting other MM (double

reset may occur).

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the other management module is being reset. This message is typically generated by a
management module that is in the process of becoming the active management module. Note that in
certain circumstances a management module may experience a double reset and reload twice. A
management module can recover automatically even if it has reloaded twice.

Recommended

Action

No action is required.

PLAT-1002

Message

MM<Identifies which MM (1 or 2) is generating the message>: <Warning message>

hk_fence 0x<MM Housekeeping Fence register. Contents are platform-specific> mm_ha

0x<MM HA register. Contents are platform-specific> mm_status 0x<MM Status

register. Contents are platform-specific>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that one of the management modules cannot access the inter-integrated circuit (I2C)
subsystem because of an error condition or being isolated from the I2C bus.

Recommended

Action

Reload the management module if it does not reload automatically. Reseat the management module if
reloading does not solve the problem. If the problem persists, replace the management module.

Advertising