Bl-1026, Bl-1027, Bl-1028 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 126

110
Network OS Message Reference
53-1003227-01
BL-1026
8
BL-1026
Message
Internal port offline during warm recovery, state <port state> (0x<port ID>).
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that an internal port went offline during warm recovery of the switch. The switch will reboot and
start a cold recovery.
Recommended
Action
Execute the copy support command and reload the switch.
Execute the diag post command to make sure Power-On Self-Test (POST) is enabled.
If the problem persists, replace the switch.
BL-1027
Message
Interface module in <slot string> faulted, boot failed; status 0x<boot status>
0x<1250 0 boot status> 0x<1250 1 boot status>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the interface module failed to boot properly.
Recommended
Action
Reload or power cycle the interface module using the power-off and power-on commands. If the
message persists, replace the interface module.
BL-1028
Message
Switch faulted; internal processor was reset before switch init completed.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the switch internal processor was reset before the initialization completed.
Recommended
Action
Reload or power cycle the switch. If the message persists, replace the switch.