Fcoe-1024, Fcoe-1029, Fcoe-1030 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 200

184
Network OS Message Reference
53-1003227-01
FCOE-1024
8
FCOE-1024
Message
FDISC received from Enode without prior FLOGI.
Message Type
DCE
Severity
WARNING
Probable Cause
Indicates that a fabric discovery (FDISC) frame is received from the end node that has not logged in. The
end node must send a fabric login (FLOGI) before it can send an FDISC.
Recommended
Action
No action is required.
FCOE-1029
Message
Version mismatch between FIP FDISC and root VN port.
Message Type
DCE
Severity
WARNING
Probable Cause
Indicates that the FCoE Initialization Protocol (FIP) version does not match between the fabric login
(FLOGI) and fabric discovery (FDISC) frames.
Recommended
Action
Make sure that the device that is trying to log in conforms to the FC-BB-5 standard.
FCOE-1030
Message
Version mismatch between FIP LOGO and root VN port.
Message Type
DCE
Severity
WARNING
Probable Cause
Indicates that the switch received an FCoE Initialization Protocol (FIP) logout (LOGO) request but the
device logged in with a different FIP version.
Recommended
Action
Make sure that the device that is trying to log in conforms to the FC-BB-5 standard.