EM-1014

8

EM-1014

Message

Unable to read sensor on <FRU Id> (<Return code>).

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the environmental monitor (EM) was unable to access the sensors on the specified
field-replaceable unit (FRU).

Recommended

Action

Reseat the FRU. If the problem persists, replace the FRU.

EM-1015

Message

Warm recovery failed (<Return code>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a problem was discovered when performing consistency checks during a warm boot.

Recommended

Action

Monitor the switch. If the problem persists, reload or power cycle the switch.

EM-1016

Message

Cold recovery failed (<Return code>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a problem was discovered when performing consistency checks during a cold boot.

Recommended

Action

Monitor the switch. If the message persists, execute the copy support command and contact your
switch service provider.