EM-1014
8
EM-1014
Message
Unable to read sensor on <FRU Id> (<Return code>).
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the environmental monitor (EM) was unable to access the sensors on the specified
field-replaceable unit (FRU).
Recommended
Action
Reseat the FRU. If the problem persists, replace the FRU.
EM-1015
Message
Warm recovery failed (<Return code>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a problem was discovered when performing consistency checks during a warm boot.
Recommended
Action
Monitor the switch. If the problem persists, reload or power cycle the switch.
EM-1016
Message
Cold recovery failed (<Return code>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a problem was discovered when performing consistency checks during a cold boot.
Recommended
Action
Monitor the switch. If the message persists, execute the copy support command and contact your