Fabr-1039, Fabr-1041, Fabr-1055 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 190

174
Network OS Message Reference
53-1003227-01
FABR-1039
8
Recommended
Action
No action is required.
FABR-1039
Message
Invalid RBridge ID zero received from principal switch (RBridge ID = <Principal
RBridge id>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that an invalid RBridge ID zero has been received.
Recommended
Action
Check the reason for the principal switch to assign an invalid RBridge ID zero.
FABR-1041
Message
Port <Port that is being disabled> is disabled due to trunk protocol error.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that a link reset was received before the completion of the trunking protocol on the port.
Recommended
Action
Toggle the port using the no fabric isl enable and fabric isl enable commands.
The port may recover by re-initialization of the link.
If the message persists, execute the copy support command and contact your switch service provider.
FABR-1055
Message
Switch <Switchname> will be taken offline and back online for RBridge Id auto
configuration to take effect.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified switch has been bounced for the RBridge ID auto configuration to take effect
on the unconfigured VCS switch.
Recommended
Action
No action is required.