Dcm-1007, Dcm-1008, Dcm-1009 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 146: Dcm-1010

130
Network OS Message Reference
53-1003227-01
DCM-1007
8
DCM-1007
Message
No Configuration File Replay.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that configuration file replay will not happen on this system boot up.
Recommended
Action
No action is required.
DCM-1008
Message
Configuration has been reset to default due to changes in configuration metadata.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the configuration schema has changed and therefore the old configuration cannot be
retained.
Recommended
Action
Replay the saved configuration manually.
DCM-1009
Message
RBridge ID is set to <Rbridge-id>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the RBridge ID has changed to the specified value.
Recommended
Action
No action is required.
DCM-1010
Message
Operation of setting RBridge ID to <Rbridge-id> failed.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates a failure while changing the RBridge ID.