Nsm-1027, Nsm-1028, Nsm-1029 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 321

Network OS Message Reference
305
53-1003227-01
NSM-1027
8
NSM-1027
Message
<SFPType> transceiver for interface <InterfaceName> is removed.
Message Type
DCE
Severity
INFO
Probable Cause
Indicates that a transceiver (SFP or CFP2) has been removed from the specified interface.
Recommended
Action
No action is required.
NSM-1028
Message
Incompatible SFP transceiver for interface <InterfaceName> is detected.
Message Type
DCE
Severity
ERROR
Probable Cause
Indicates that an incompatible small form-factor pluggable (SFP) transceiver for the interface has been
inserted.
Recommended
Action
Disable the interface using the shutdown command and insert an SFP transceiver that is supported on
the interface. After the SFP transceiver is inserted, re-enable the interface using the no shutdown
command.
NSM-1029
Message
Failed to read SFP transceiver for interface <InterfaceName>.
Message Type
DCE
Severity
ERROR
Probable Cause
Indicates failure to read the small form-factor pluggable (SFP) transceiver for the specified interface.
Recommended
Action
Disable the interface using the shutdown command and re-insert the SFP transceiver. After the SFP
transceiver is inserted, re-enable the interface using the no shutdown command. If the problem persists,
contact your switch service provider.