C2-1008, C2-1009, C2-1010 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 133

Network OS Message Reference
117
53-1003227-01
C2-1008
8
Recommended
Action
No action is required.
C2-1008
Message
S<slot number>,P<port number> (<interface module port number>): QoS overwrites
vc-link-init idle. ARB will be used on the link.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that quality of service (QoS) overwrites the fill word IDLE used in the long distance links.
Arbitrated loop (ARB) will be used on the link.
Recommended
Action
No action is required.
C2-1009
Message
S<slot number>,P<port number> (<interface module port number>): vc-link-init arb
overwrites fill word IDLE. ARB will be used on the link.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the vc-link-init arb command has overwritten the fill word IDLE. Arbitrated loop (ARB) will
be used on the link.
Recommended
Action
No action is required.
C2-1010
Message
S<slot number>,C<chip index>: Internal monitoring of faults has identified suspect
hardware, interface module may need to be reset or replaced:
fault1:<fault1_count>, fault2:<fault2_count>, thresh2:0x<threshold_used>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that above normal errors were observed in hardware that may or may not impact the data
traffic.
Recommended
Action
Whenever the error is observed persistently, power cycle the specified interface module using the
power-off and power-on commands. If the problem persists, replace the interface module.