EANV-1004
8
EANV-1004
Message
C<chip index>: Invalid DMA ch pointer, chan:<Channel number>, good_addr:0x<Good
address> bad_addr:0x<Bad address>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.
Recommended
Action
No action is required. The software will recover from the error.
EANV-1005
Message
C<chip index>,A<eanvil id>: Memory allocation failed.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates memory allocation failure in the software.
Recommended
Action
Reload the system at the next maintenance window. If the problem persists, replace the switch or contact
your switch service provider.
EANV-1006
Message
C<chip index>: HW ASIC Chip fault. Type = 0x<chip error type>, Error = <chip error
string>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that renders the
chip not operational.
Recommended
Action
Reload the system at the next maintenance window. If the problem persists, replace the switch or contact
your switch service provider.