Em-1037, Em-1042, Em-1043 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 176

160
Network OS Message Reference
53-1003227-01
EM-1037
8
Recommended
Action
Reseat the FRU card.
If the problem persists, reload or power cycle the switch.
Execute the diag systemverification command to verify that the switch does not have hardware
problems.
If the problem still persists, replace the FRU.
EM-1037
Message
<FRU Id> is no longer faulted.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified power supply is no longer marked faulty; probably because its AC power
supply has been turned on.
Recommended
Action
No action is required.
EM-1042
Message
Important FRU header data for <FRU Id> is invalid.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified field-replaceable unit (FRU) has an incorrect number of sensors in its FRU
header-derived information. This could mean that the FRU header was corrupted or read incorrectly, or it
is corrupted in the object database, which contains information about all the FRUs.
Recommended
Action
Reseat the FRU. If the problem persists, replace the FRU.
EM-1043
Message
Cannot power <FRU Id> <state (on or off)>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified field-replaceable unit (FRU) could not be powered on or off. The FRU is not
responding to commands.
Recommended
Action
Reseat or replace the FRU.