Em-1068, Em-1069, Em-1070 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 180

164
Network OS Message Reference
53-1003227-01
EM-1068
8
EM-1068
Message
High Availability Service Management subsystem failed to respond. A required
component is not operating.
Message Type
FFDC | LOG
Severity
ERROR
Probable Cause
Indicates that the high availability (HA) subsystem has not returned a response within 4 minutes of
receiving a request from the environmental monitor (EM). This event usually indicates that some
component has not started properly or has terminated. The specific component that has failed may be
indicated in other messages or debug data. There are serious internal Network OS configuration or
hardware problems on the switch.
Recommended
Action
Reload or power cycle the switch.
If the message persists, execute the copy support command and contact your switch service provider.
EM-1069
Message
<FRU slot identifier> is being powered off.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified interface module has been intentionally powered off.
Recommended
Action
No action is required.
EM-1070
Message
<FRU slot identifier> is being powered on.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified interface module has been intentionally powered on.
Recommended
Action
No action is required.