Bosch 8-Dec User Manual

Page 131

Advertising
background image

Arming Devices | Conventional | 123

The input unit should primarily be installed flush-

mounted.

Parts Included

Type

Qty.

Component

SE 100 GLT

1

Control unit

1

Reader

Technical Specifications

SE 100 GLT control unit

Operating voltage

10.8 V to 30 V

Total current consumption including blocking element and reader

Standby armed

53 mA

Standby disarmed

68 mA

When being engaged

140 mA for 300 ms

When blocking

200 mA for 200 ms

Environmental conditions

Protection category

IP 30

Operating temperature

-5 °C to +45 °C

Storage temperature

-40 °C to +85 °C

Housing

Material

ABS

Color

RAL 9002

Dimensions (H x W x D)

160 x 135 x 35 mm

Weight

0.25 kg

Reader
Range

Max. 20 mm

Frequency

125 kHz

Transmission power

250 mW

Transmission power

250 mW

Cable to control unit

Max. 6 m, 6-pin, shielded,

permanently cast

Environmental conditions

Environmental class

3

Protection category

IP 65

Operating temperature

-25 °C to +70 °C

Storage temperature

-40 °C to +85 °C

Housing

Material

ASA Luran S

Color

Titanium white (similar to RAL 9010)

Dimensions (H x W x D)

For installation in 55 mm

surface-mounted/flush-mounted

junction box

80 x 80 x 30 mm

Weight

0.35 kg

Ordering Information

SE 100 GLT SmartKey Arming Device

For arming/disarming an intrusion alarm sys-

tem via the reader as a system solution

IUI-SKCU1C-100

Accessories

Kit for recessed mounting (door frame)

4998021691C20

Kit for surface mounting, space for
magnetic contact

4998013609C20

Kit for upgrading NBS 10

4998040651C20

Blocking element

4998149110

Kit for mounting in glas doors

4998019339C20

www.boschsecurity.com