Ds160 series high performance request‑to‑exit, Detectors – Bosch 8-Dec User Manual

Page 221

Advertising
background image

Detectors and Accessories | Request-to-Exit | 213

DS160 Series High

Performance

Request‑to‑exit Detectors

Features

Door monitor with sounder alert
Sequential Logic Input (SLI)
Internal vertical pointability
Wrap-around coverage pattern with precise pattern

control

Up to 64 second adjustable latch time
Selectable relay trigger mode
Selectable fail-safe or fail-secure modes
Adjustable sounder volume
Activation LED

The DS160 Series consists of the DS160 Detector (light
gray) and the DS161 Detector (black) specifically designed
for Request-to-exit (REX) applications. With features such
as timers, door monitor with sounder alert, and pointable
coverage, the DS160 and DS161 have the flexibility to meet
the most stringent REX requirements. The exclusive
Sequential Logic Input (SLI) provides added security that is
not offered in any other REX device.

Functions

Sequential Logic Input (SLI)
The SLI terminal allows connection of a second device to
require sequential detection. This eliminates the possibility
that an object that is slid through the door or underneath
the door will activate the detector. This input can also be
used to lock the sensor if motion is present outside the
premises.

Door Monitor
The sensor can monitor a door contact to allow special
control of the internal relay. For example, if the door is
opened within the relay time period, the sensor can be
programmed to halt the timer. If the door is not opened
within a specific time period, the relay can be programmed
to deactivate.
Sounder Alert
An integrated sounder can be programmed to activate if the
door is left open too long. The sounder volume is fully
adjustable to 85 dB.
Keycard Input
The keycard input allows the sensor relay to be controlled
from an external source, such as an access control system
or card reader.

Certifications and Approvals

Region

Certification

Europe

CE

89/336/EEC, EN55022: 1998 +A1: 2000
+A2: 2003, EN50130-4: 1996 +A1: 1998
+A2: 2003, EN61000-4-2: 1995 +A1:
1998 +A2: 2001, EN61000-4-3: 2002
+A1: 2003, EN61000-4-4: 1995 +A1:
2000 +A2: 2001, EN61000-4-5: 1995
+A1: 2001, EN61000-4-6: 1996 +A1:
2001 +A2: 2001, EN61000-4-11:1994
+A1: 2001, EN60950-1: 2001

Poland

CNBOP

DS160

USA

UL

ALVY: Access Control Systems Units
(UL294)

Europe

Complies with EN50131‑1 Grade 2

Installation/Configuration Notes

Front View
Mounted on wall above door and mounted on ceiling .75 m
(2.5 ft) in front of the door.

www.boschsecurity.com

Bosch Security Systems B.V.

5