Mk 48 sz surface-mount magnetic contact – Bosch 8-Dec User Manual

Page 288

Advertising
background image

280 | Detectors and Accessories | Magnetic Contacts Surface Mount

MK 48 SZ surface-mount

magnetic contact

Features

▶ Conventional surface-mount magnetic contact
▶ VdS class C
▶ Tamper switch
▶ Parallel installation, surface mounted and flush

mounted

▶ Conventional perimeter protection
▶ Can be used in the SPE blocking element (installed on

frames/doors) according to VdS Class C

Conventional magnet contacts are used for tear-off
surveillance of windows and doors.

Certifications and Approvals

Region

Certification

Europe

CE

MK 48 S Z

Germany

VdS

G 191019, C MK 48 S Z

Installation/Configuration Notes

Installation notes

•

Magnetic contact and magnet are mounted parallel to

each other using the surface-mount or flush-mount

housing.

•

When inserting the contact housing, please ensure that

the labeling stud on the face is pointing toward the

magnet, regardless of the type of installation.

•

The distance between the contact and the magnet must

be between 7 mm and 16 mm; 12 mm is preferred.

•

Installation in ferromagnetic materials is not

permissible.

•

Installation can be completed with or without a plastic

sleeve. If no plastic sleeve is used, the components

should be fixed in the bores.

1

Contact

2

Magnet

3

Axial installation offset

Distances diagram

1

Extraction

2

Proximity switch part

3

Secure area

4

Tolerance

5

Tamper area

Parts Included

Type

Qty.

Components

MK 48 S Z

1

Surface-mount magnetic contact

Magnet (8 x 8 x 40 mm) incl. 2x surface

mounting housing,

2 caps with 4 bases

Bosch Security Systems B.V.

www.boschsecurity.com

5

Advertising