Bosch 8-Dec User Manual

Page 93

Advertising
background image

Accessories for Control Panels and Keypads | Interface Modules | 85

Functions

Communication Formats

ADT-SIA
BFSK (2300Hz ACK Tone or 1400Hz ACK Tone)
DTMF (Contact ID, High Speed and 4/2 Express)
FBI Superfast DTMF (1400 Hz ACK Tone or 2300 Hz ACK Tone)
Pulse 3/1, 3/1 Checksum, 4/2 (1400 Hz ACK Tone or 2300 Hz ACK Tone)
Radionics Modem II, Radionics Modem IIe , and Modem IIIa

2

Seriee FSK and DTMF
SIA V.21, 110/300 baud
SIA Bell 103, 110/300 baud
Robofon
Telim

Inputs

Input Description
1

Used as an end-of-line (EOL) supervised loop. Detects open, short,

and normal states. Terminate this input with a 10 kΩ EOL resistor.

2

Used for intercept inhibit to force the C900V2 into Fallback mode

for at least two minutes.

3

Used for intercept override, allowing users to switch between in-

tercept and fallback modes.

Outputs

Out-
put

Description

1

Provides local annunciation if the power to the C900V2 is lost or

the CPU fails.

2

Provides local annunciation if the connection to the monitoring

center is lost.

3

Provides local annunciation whenever the C900V2 is in intercept

mode.

4

Controllable from the monitoring center and the Conettix D6200

Programming/Administration Software (default is open).

Intercept and Fallback Modes

Intercept Mode: The C900V2 connects the dialer to the

network. Intercept mode remains on as long as the

C900V2 remains in continuous contact with the

Conettix D6600 Communications Receiver/Gateway.

Fallback Mode: The C900V2 connects the dialer to the

telephone line, removing itself from the telephone

circuit. Fallback mode occurs if the C900V2 loses

contact with the Conettix D6600 Communications

Receiver/Gateway, loses power, or stops operating

correctly.

LED Indicators
The C900V2 has two dual-colored LEDs that indicate the
module's status (the SYSTEM LED and the DIALER LED).
Modular Jacks
The C900V2 module has three modular jacks.

Panel Jack: Connects to a dialer through a modular

telephone cord (D162).

TELCO Jack: Connects to a PSTN line through a

modular telephone cord (D162).

Ethernet Jack: Connects to the Ethernet data network

through an Ethernet cable. For 10BASE-T, the cable

must be Category 3 or better. For 100BASE-T, the cable

must be Category 5 or better.

Polling and Supervision
Conettix C900V2 polling helps the Conettix D6600
Communications Receiver/Gateway to perform
supervision.
Web Programming Tool

The web programming tool makes the C900V2 configuration
process simple and convenient, similar to browsing a web site.
After obtaining an Application ID, installers can go to
www.c900v2.com from a computer with internet access and
configure the C900V2 for the preferred central station.

Certifications and Approvals

Region

Certification

Europe

CE

1999/5/EC, EN55022: 1998,
EN50130-4: 1996 +A1: 1998 +A2: 2003,
EN60950-1: 2001, EN61000-3-2,
EN61000-3-3, EN61000-4-2: 1995 +A1:
1998, EN61000-4-3: 1995 +A1: 1998,
EN61000-4-4: 1995, EN61000-4-5:
1995, EN61000-4-6: 1996,
EN61000-4-11: 1994, TBR21: 1998

Belgium

INCERT

B-509-0040/a

USA

UL

AMCX: Central Station Alarm Units
(UL1610, UL1635), AMCX7: Central
Station Alarm Units Certified for Canada
(cULus), APAW: Police Station Alarm Units
(UL365, UL464), APAW7: Police Station
Alarm Units Certified for Canada (cULus),
APOU: Proprietary Alarm Units (UL1076),
APOU7: Proprietary Alarm Units Certified
for Canada (cULus), NBSX: Household
Burglar Alarm System Units (UL1023),
NBSX7: Household Burglar Alarm System
Units Certified for Canada (cULus), UTOU:
Control Units and Accessories - Household
System Type (UL985), UTOU7: Control
Units and Accessories - Household System
Type Certified for Canada (cULus)
UL864, 9th edition

FM
CSFM

7300-1615: 180 and 7167-1615:
223 July 2008

www.boschsecurity.com

Bosch Security Systems B.V.

2

Advertising