Conettix - Information Transport Solutions | Conettix - AT2000/ATE | 417

AT 2000 Analog Transmis-

sion System

Features

7 parallel inputs, 2 outputs (12 in/12 out optional)
Programmable with PC software (WPAT)
Tone and pulse dialing methods
Tamper and blockade release

The AT 2000 Analog and AFS auto dialers and
communicators handle the analog transmission of danger
alarms, technical alarms/statuses via telecommunication
networks.

Functions

Network ac-
cess

Transmission
procedure

Transmission
protocol

Receiver

Analog net-

work

Analog

10 bits/sec.

Telim

Analog

monitoring station

BOSCH

300 bits/sec.

Analog

monitoring station

Data transmis-

sion to TAP/UCP

server

Euromessage

message (tone

dialing)

Euromessage

receiver

In the event of tampering or damage to the relaying
telephone line, the AT 2000 can send a message (tamper
release).
The absolute operating procedure on the telephone line is
enabled by the blockade release.
Monitoring of the auto dialer and the telephone network
occurs through a routine call.
The AT 2000 has a tamper contact.
Power monitoring: network, battery, undervoltage

The event storage for up to 31 events can be read out using
a PC.
AT 2000 AFS

In addition, the AT 2000 AFS can handle the remote-

control of outputs with the BOSCH transmission

procedure.

The four outputs (relays) can be controlled depending

on the message line status (locally) and via remote

control by reception and transmission equipment using

the Bosch procedure.

Certifications and Approvals

Region

Certification

Europe

CE

AT 2000 Analog/AFS

Germany

VdS

G 196808 AT 2000 Analog

Installation/Configuration Notes

Telephone line

The AT 2000 Analog enables connection to main and

auxiliary lines and is connected to the telephone line via

a TAE junction box.

Fire detection technology

Interface according to VDE 0833 part 2 can be provided

optionally.

Parts Included

Type

Qty.

Component

AT 2000 Analog

incl. housing and

power supply

1

Analog alarm transceiver

with housing and power supply

AT 2000 Analog

incl. housing

1

Analog alarm transceiver

with housing (without power supply)

AT 2000 Analog

Installation module

1

Analog alarm transceiver

Installation module (without housing and

power supply)

AT 2000 AFS

Installation module

1

Analog/remote-controlled alarm transceiver

Installation module (without housing and

power supply)

Technical Specifications

Housing versions and installation modules
Operating voltage

10.5 V to 14.5 V

Current consumption

Standby current

Approx. 60 mA

Transmission mode

Approx. 85 mA

Additional current per activated

relay

Approx. 12 mA

Trigger resistance

5.62 kilohm ±1%

Activation time

> 200 ms

www.boschsecurity.com

Bosch Security Systems B.V.

7

Advertising