278 | Detectors and Accessories | Magnetic Contacts Surface Mount

EMK 46 AT Z Surface-

Mount Magnetic Contact

Features

Conventional surface-mount magnetic contact
VdS class B
Head-on or parallel surface mounting
Conventional perimeter protection

Conventional magnet contacts are used for tear-off
surveillance of windows and doors.

Certifications and Approvals

Region

Certification

Europe

CE

EMK 46 AT Z

Germany

VdS

G 191563, B EMK 46

Installation/Configuration Notes

Installation notes
Installation can be head-on or parallel on the door or
window frames.

1

Contact

2

Magnet

3

Installation offset

Surface mounting

When used on metal frames, the plastic bases must be

used.

The supply lines need to be measured electrically

before connection.

The contact and the magnet (6 x 30 mm) can only be

inserted in the surface mounting housing in conjunction

with the plastic sleeve.

Installation on ferromagnetic materials is only

permissible with the washer components supplied.

Lateral installation offset: max +/- 3 mm.

Distances diagram
Surface mounting with magnet 6 x 30 mm

1

Extraction

2

Proximity switch part

Flush mounting

Installation in ferromagnetic materials is not

permissible.

Installation can be completed with or without a plastic

sleeve. If no plastic sleeve is used, the components

should be fixed in the bores.

Distances diagram
Head-on installation with magnet 6 x 30 mm

1

Extraction

2

Proximity switch part

Parts Included

Type

Qty.

Component

EMK 46 AT Z

1

Surface-mount magnetic contact

incl. flange, sleeves, and surface-mounting

housing with accessories

Bosch Security Systems B.V.

www.boschsecurity.com