160 | Detectors and Accessories | Motion PIR

Top View
Standard Broad Coverage: 10 m x 10 m (35 ft x 35 ft)

Side View
Standard Broad Coverage: 10 m x 10 m (35 ft x 35 ft)

Top View
Optional Barrier Coverage: 10 m x 3 m (35 ft x 10 ft)

SideView
Optional Barrier Coverage: 10 m x 3 m (35 ft x 10 ft)

Top View
Optional Long Range Coverage: 21 m x 3 m (70 ft x 10 ft)

Side View
Optional Long Range Coverage: 21 m x 3 m (70 ft x 10 ft)

Technical Specifications

Enclosure Design

Dimensions:

10.8 cm x 7 cm x 4.6 cm

(4.25 in. x 2.75 in. x 1.8 in.)

Environmental Considerations

Temperature

(Operating):

-29°C to +49°C (-20°F to +120°F)

For UL Listed Applications, 0°C to + 49°C (+32°F to

+120°F)

Radio Frequency

Interference

(RFI) Immunity:

No alarm or setup on critical frequencies in the range from

26 MHz to 950 MHz at 50 V/m.

Mounting

Height (recommended):

2 m to 2.6 m (6.5 ft to 8.5 ft)

Location:

Surface or corner mount.

Ceiling mount with the appropriate mounting

bracket.

Internal Pointability:

Coverage is adjustable ±10° horizontally, +1°

to -18° vertically.

Outputs

Alarm:

Signals through the multiplex bus

Tamper:

A tamper condition is signaled through the multiplex bus and

displays at the keypads.

Power Requirements

Current Draw (two-

wire):

LED off: <0.4 mA draw on MUX bus

LED on: 2 mA draw on MUX bus

Current Draw (four-

wire):

LED off: <0.4 mA draw on MUX bus

0 mA draw on Aux. power

LED on: <0.4 mA draw on MUX bus

3 mA draw on Aux. power

Input (Voltage):

Connects directly to the multiplex (MUX) bus of the

control panel and optionally to an auxiliary 12 VDC

source

Standby Power:

There is no internal standby battery. Connect to DC

power sources capable of supplying standby power if

primary power fails. For each hour of standby time

needed, 0.4 mAh are required. For UL Listed Require-

ments, four hours (1.4 mAh) minimum are required.