Detectors and Accessories | Magnetic Contacts Surface Mount | 283

MSA-LZS Surface-Mount

Magnetic Contact

Features

Conventional surface-mount magnetic contact
VdS class C
Tamper switch
Parallel or head-on surface mounting
Conventional perimeter protection

Conventional magnetic contacts are used for opening
surveillance of windows and doors.

Certifications and Approvals

Region

Certification

Europe

CE

MSA-LZS

Germany

VdS

G 191100, C MS/MSA-LZS

Installation/Configuration Notes

Installation notes

Installation can be parallel or head-on.

The AG 4 surface mounting housing makes it possible

to install on ferromagnetic materials.

1

Contact

2

Magnet

3

AG4 surface mounting housing

4

Plastic part

5

Offset in the axial direction

6

Warning! The adjustment mark must point to the magnet.

Parts Included

Type

Quant. Component

MSA-LZS

1

Surface-mount magnetic contact with mag-

net incl. 6 m cable and AG4 surface mount-

ing housing with accessories

Technical Specifications

Type of installation

Surface mount, parallel or head-on

Contact

Normally open contact/toggle switch

Permitted contact load

≤ 3 Watt

Switching current

10 A to 100 mA

Switching voltage max.

≤ 30 V_

Switch tolerance

≥ 10

7

Magnet

AlNiCo 500

Switch dimension:

43 x 12 x 12 (mm)

Magnet dimension:

Ø 8 mm x 20 mm

Parallel installation distance:

2 to 6 mm

Temperature range

-25 °C to +70 °C

Connection cable

6 m, LiYY 4 x 0.14 mm

Protection type

IP68