Bosch 8-Dec User Manual

Page 141

Advertising
background image

Arming Devices | LSN | 133

Installation/Configuration Notes

Number of SmartKey keys
A maximum of 16 SmartKey keys can be used per system if
the SmartKey key is read in at the reader. In other respects,
the number of SmartKey keys depends on the control panel:
NZ 300 LSN = 40 keys, UEZ = 255 keys.
SE 320 LSNi without bolt contact
Due to the time shift caused by the LSN, up to four
SE 320 LSNi can be activated in 200 ms (not arming time).
In general, a bolt contact should be mounted.
SPE blocking element

If several LSN SmartKey systems need to block

simultaneously in one area (motorized block locking

function), the control units must be in the same LSN

processing assembly (on LVM for UEZ, on NV 120 for

UGM).

The SPE blocking element is always mounted in the

secure area with a mounting kit.

Connection options

E4.4 blocking elements for vault doors/conversion kit:

When connecting an E4.4 blocking element/conversion

kit, no SPE blocking element or door opener relay may

be connected.

Door opener relay: When connecting a door opener

relay, no E4.4 blocking element/conversion kit may be

connected for vault doors.

Push-button for door opener relay: A lockable code

keypad cannot be connected when connecting a push-

button for the door opener.

Activation switching point
There is a freely programmable C point switch output
(open-collector output) 12 V, max. 80 mA on the control
unit. The max. length for a connected cable is 3 meters.
The yellow LED on the SmartKey code keypad is connected
to the C point as standard. An appropriate series resistor is
fitted for connecting the C point to the yellow LED on the
SmartKey code keypad. If the C point is assigned for a use
other than the yellow LED on the SmartKey code keypad,
this series resistor must be bypassed by connecting the
solder points (back of circuit boards).

Parts Included

Type

Qty.

Component

SE 320 LSNi

1

SmartKey arming device

control unit

Technical Specifications

SE 320 LSNi control unit

Operating voltage

9.6 V to 30 V

Total current consumption including blocking element at an

input voltage of 9.6 V

Standby LSN part

3.53 mA

Standby additional supply

41 mA

Bolt is engaged

110 mA for 200 ms

Bolt blocked

470 mA for 200 ms

Total current consumption including blocking element at an

input voltage of 28 V

Standby LSN part

3.53 mA

Standby additional supply

30 mA

Bolt is engaged

65 mA for 200 ms

Bolt blocked

200 mA for 200 ms

C-point switch output

(open collector output)

12 V, max. 80 mA. The max. length

for a connected cable is 3 meters.

Relay outputs with 2 changeover contact sets

Switching performance

60 W DC (2 A, 30 V DC)

Activation current with input

voltage 9.6 V

20 mA

Activation current with input

voltage 28 V

8 mA

Environmental conditions

Environmental class

2

Protection category

IP 30

Operating temperature

-5 °C to +45 °C

Storage temperature

-40 °C to +85 °C

Housing

Material

ABS

Color

RAL 9002

Dimensions (H x W x D)

160 x 135 x 35 mm

Weight

0.25 kg

Ordering Information

SE 320 LSNi SmartKey Arming Device

For arming/disarming an intrusion alarm sys-

tem via a code keypad with integrated reader

or just with a code keypad as a system solution

IUI-SKCU3L-320

www.boschsecurity.com

Bosch Security Systems B.V.

4

Advertising