Detectors and Accessories | Magnetic Contacts Recessed Mount | 261

EMK 46 Z Built-in magnetic

contact

Features

▶ Conventional flush-mount magnetic contact
▶ VdS class B
▶ Head-on or parallel flush mounting
▶ Conventional perimeter protection
▶ Can be used in the SPE blocking element (installed on

frames/doors) according to VdS Class B

Conventional magnetic contacts are used for opening
surveillance of windows and doors.

Certifications and Approvals

Region

Certification

Europe

CE

EMK 46 Z

Germany

VdS

G 191563, B EMK 46

Installation/Configuration Notes

Installation notes

•

Installation is head-on or parallel in door or window

frames.

•

Installation can be completed with or without a plastic

sleeve. If no plastic sleeve is used, the components

should be fixed in the bores.

•

Installation in ferromagnetic materials is not

permissible.

•

The supply lines need to be measured electrically

before connection.

1

Contact

2

Magnet

3

Installation offset

Distances diagram

1

Extraction

2

Proximity switch part

Parts Included

Type

Qty.

Component

EMK 46 Z

1

Recessed mount magnetic contacts

incl. flange and sleeves

Technical Specifications

Type of installation

Flush, head-on or parallel

Permissible operating voltage

Max. 40 V_

Contact type

1-pin (normally) open contact

Permissible contact load

6 VA

Max. 100 V

Max. 500 mA

Protection category

IP 67
VdS environmental class IV

Permissible

ambient temperature

-25 °C to +70 °C

Housing

•

Material

ABS

•

Color

White

Dimensions

•

Contact

6 x 30 mm (Ø x L)

•

Magnet

6 x 30 mm (Ø x L)

•

Plastic sleeve

8 x 31 mm (Ø x L)

•

Connection cable

Ø 3.2 mm, 6 m long