Bosch 8-Dec User Manual

Page 174

Advertising
background image

166 | Detectors and Accessories | Motion PIR/Microwave

Installation/Configuration Notes

Long-range Coverage 18 m x 25 m (60 ft x 80 ft)

Selectable Short-range Coverage 8 m x 10 m (25 ft x 33 ft)

Mounting Considerations
The recommended mounting height is 2 m to 3 m (7 ft to
10 ft).

Use an optional B328 Gimbal-mount Bracket or B335-3
Low-profile Swivel-mount Bracket to surface-mount the
detector on a flat wall or in a corner.
Use an optional B338 Universal Ceiling Bracket to mount
the detector on the ceiling.
Wiring Considerations
Recommended wire size is 0.2 mm

2

to 1 mm

2

(26 AWG to

16 AWG).

Parts Included

Quantity Component
1

Detector

2

Flat-head screws

2

Screw anchors

1

Nylon cable tie

1

Pattern Mask

1

Installation Guide

Technical Specifications

Electrical

Power Requirements
Voltage (Operating):

9 VDC to 15 VDC

Current (Maximum):

< 25 mA

Current (Standby):

13 mA

Outputs
Relay:

Solid state relay, normally-closed (NC) con-

tacts power supervised.

3 W, 125 mA, 25 VDC, resistance < 10 Ω.

Tamper:

Normally-closed (NC) contacts (with cover

on) rated at 25 VDC, 125 mA maximum.

Connect tamper circuit to 24-hour protec-

tion circuit.

Trouble:

Solid‑state relay normally-closed (NC) con-

tacts.

Mechanical

Enclosure Design
Color:

White

Dimensions:

136 mm x 69 mm x 58 mm

(5.25 in. x 2.75 in. x 2.25 in.)

Material:

High-impact ABS plastic

Indicators
Alarm Indicator:

Blue LED for TriTech+ alarms

Yellow LED for microwave alarms

Red LED for PIR alarms

Zones
Zones:

86

Frequency Information
Radio Frequency Interference

(RFI) immunity:

No alarm or setup on critical frequencies in

the range from 26 MHz to 1 GHz at 50 V/m.

Bosch Security Systems B.V.

www.boschsecurity.com

5

Advertising