Ism‑bld1 blue line tritech detectors, Ism‑bld1 blue line tritech detec- tors – Bosch 8-Dec User Manual

Page 180

Advertising
background image

172 | Detectors and Accessories | Motion PIR/Microwave

ISM‑BLD1

Blue Line TriTech Detec-

tors

Features

11 m x 11 m (35 ft x 35 ft) broad coverage
EN50131-2-4 Grade 2 compliant
Dual detection technologies with advanced signal

processing

Flexible mounting height from 2.3 m to 2.7 m (7.5 ft to

9 ft)

No range or height adjustments required
Supervised microwave; microwave range can be

adjusted

Eight detection layers including optional look-down

zone

Draft and insect immunity
Temperature compensation
Combined cover and wall tamper

The ISM-BLD1 TriTech® Detectors use a combination of
passive infrared (PIR) and microwave detection
technologies with advanced signal processing. These
unobtrusive detectors are simple to install and do not need
field adjustments.
These detectors are available in three frequencies:

Frequency

Detector

9.9 GHz

ISM-BLD1- F3

10.525 GHz

ISM-BLD1- F1

10.687 GHz

ISM-BLD1- F4

Functions

Advanced Signal Processing
Adaptive processing adjusts to background disturbances,
reducing false alarms without sacrificing intruder detection.
First Step Processing (FSP) almost instantly responds to
human targets without producing false alarms from other
sources. FSP adjusts the detector's sensitivity based on
signal amplitude, polarity, slope, and timing. This eliminates
the need for the installer to select the sensitivity level. Each
sensor (PIR and microwave) processes signals individually,
and both sensors must agree there is an alarm before the
alarm relay activates.
Test Features
An externally-visible, tricolor (blue, yellow, green) alarm
LED (light-emitting diode) indicates each sensor's status.
Supervised Microwave
The microwave circuit is fully-supervised. If the microwave
subsystem fails, the PIR subsystem provides single
technology coverage.
Draft and Insect Immunity
The sealed optical chamber prevents drafts and insects
from affecting the detector.
Temperature Compensation
The detector adjusts its sensitivity to maintain its ability to
identify human intruders at critical temperatures.

Certifications and Approvals

Region

Certification

Belgium

INCERT

ISM-BLD1-F1: B-509-0014/c

Russia

GOST

ISM-BLD1-F1: GOST 12997-84, GOST R
50009-2000, GOST R 51317.3.2-99,
GOST 51317.3.3-99, GOST R MEK
60065-2002

France

AFNOR

ISM-BLD1-F3: NF, A2P (282112-00)

Brazil

ANATEL

ISM-BLD1-F1: 0251-06-1855

Europe

ISM-BLD1-F1 complies with EN50131-2-4 Grade 2

Installation/Configuration Notes

Application Information
Coverage Patterns

Note

An alarm occurs only when an intruder is
detected in areas in which the PIR and
microwave patterns overlap.

Bosch Security Systems B.V.

www.boschsecurity.com

5