Bosch 8-Dec User Manual

Page 192

Advertising
background image

184 | Detectors and Accessories | Motion Outdoor

Certifications and Approvals

Region

Certification

Europe

CE

89/336/EEC, EN55022: 1998 +A1:2000
+A2:2003, EN50130-4: 1996 +A1:1998
+A2:2003, EN61000-3-3: 1995
+A1:2001, EN61000-4-2: 1995
+A1:1998 +A2:2001, EN61000-4-3:
2002 +A1:2002, EN61000-4-4: 1995
+A1:2000 +A2:2001, EN61000-4-5:
1995 +A1:2001, EN61000-4-6: 1996
+A1:2001, EN61000-4-11" 1994
+A1:2001, EN300 440-1 V1.3.1:
2001-09, EN300 440-2 V1.1.1: 2001-09

Belgium

INCERT

B-509-0038

Poland

CNBOP

58/03

Russia

GOST

OD850-F1 only: DE.AE63.B03457

USA

UL

OD850-F1 only: ANSR: Intrusion Detection
Units (UL639), ANSR7: Intrusion
Detection Units Certified for Canada (ULC-
S306)

FCC

OD850-F1 only: ESVOD850-F1

China

CCC

OD850-F1-CHI only:
2004031901000039

Brazil

ANATEL

OD850-F1 only: 0873-03-1855

Singapore

iDA

OD850-F1 only: #LPREQ-S0155-2004

Australia

C-tick

Europe

IEC

IP=54 per IEC 60529

OD850-F2 only: Complies with EN50131-1 grade 2

Installation/Configuration Notes

Top View
Standard Broad Coverage: 15 m x 15 m (50 ft x 50 ft)

Side View
Standard Broad Coverage: 15 m x 15 m (50 ft x 50 ft)

Mounting Considerations

Wall Mounting: The OD850 detectors can be mounted

directly on a wall or on the supplied B335 Swivel Mount

Bracket. Alternatively, they can be mounted directly on

a standard rectangular electrical box.

Ceiling Mounting: The detectors can be mounted on a

ceiling using the optional B338 Ceiling-Mount Bracket.

Power Considerations

Power Limits: Input power must be provided by an

Approved Limited Power Source. All outputs must be

connected to SELV (safety extra-low voltage) circuits

only.

Standby Power: This detector has no internal standby

battery. For UL Listed product installations, 4 hr

(248 mAh) of standby power must be supplied by the

control unit or by a UL Listed burglary power supply.

Technical Specifications

Enclosure Design

Dimensions:

16.5 cm x 8.25 cm x 6.35 cm

(6.5 in. x 3.25 in. x 2.5 in.)

Material:

Polycarbonate

Properties:

Weather and vandal resistant

Weight:

1.4 oz (40 g)

Environmental Considerations

IP Rating:

54

Relative Humidity:

0% to 95% non-condensing

Temperature (Operating):

-40°C to +54°C (-40°F to +130°F)

OD850-F2:

Complies with Environmental Class III

(EN50130-5)

Outputs

Alarm:

Do not use with capacitive or inductive loads.

Form A: Normally-closed contact opens on alarm.

Form C: Timed relay contact alternates state on alarm and fol-

lows an installer programmable timer.

Contact Rating: 3 W, 125 mA maximum, 25 VDC maximum for

DC resistive loads; and protected by a 4.7 Ω, ½ W resistor in the

common C leg of the relay.

Tamper: Normally-closed (with cover on) contacts rated 125 mA maxi-

mum, 25 VDC maximum

Power Requirements

Current:

62 mA maximum

Input Power:

10 VDC to 15 VDC at 22 mA standby.

Bosch Security Systems B.V.

www.boschsecurity.com

5

Advertising