Ds304 pir detector with replaceable mirrors – Bosch 8-Dec User Manual

Page 170

Advertising
background image

162 | Detectors and Accessories | Motion PIR

DS304 PIR Detector with

Replaceable Mirrors

Features

First step processing
Temperature compensation
Adjustable and replaceable mirrors
Two coverage patterns
Three mounting options
Solid state relay output
Alarm memory
Walk test remote control

The DS304 Passive Infrared (PIR) Detector uses first step
processing to reduce false alarms. The detector's mirrors,
coverage patterns, and mounting options provide
installation flexibility.

Functions

First Step Processing
First step processing (FSP) responds to human intruders
while ignoring other sources of motion, minimizing false
alarms. You do not need to select the sensitivity levels for
the application because FSP adjusts the detector’s
sensitivity based on signal amplitude, polarity, slope, and
timing.
Adjustable and Replaceable Mirrors
You can remove and replace the mirrors. You can also adjust
the vertical angle of the mirror to a recommended angle
according to the mounting height of the detector and the
type of mirror.

Test Features
The DS304 Detector has an external alarm LED (light
emitting diode). Walk test remote control means that you
can enter a command at the control panel to activate the
walk test LED.
Alarm Memory
Provides indication of stored alarms. Controlled by a
switched voltage from the control panel.

Certifications and Approvals

Region

Certification

Europe

CE

89/336/EEC, EN55022: 1998,
EN50130-4: 1996, IEC 1000-4-2: 1995,
IEC 1000-4-3: 1997, IEC 1000-4-4:
1995, IEC 1000-4-5: 1995, IEC
1000-4-6: 1996
73/23/EEC, 73/23/EEC Annex 1,
EN60950-1, EN60825

Belgium

INCERT

B-509-0023

Poland

CNBOP

103/03

France

AFNOR

NF, A2P (262252-00)

Sweden

INTYG

Nr05-135

Europe

Complies with EN50131-1 grade 2

Installation/Configuration Notes

Mounting Considerations

Mount the detector in an area where an intruder must

move across the coverage pattern.

Mount the detector within the height range of 2 m to

2.6 m; the recommended height is 2.3 m.

Mount multiple detectors so that the coverage pattern

from each detector intersects with another coverage

pattern.

Do not mount the detector on or near windows.

Do not mount the detector directly in sunlight, in hot

air, or in cold air.

Do not mount the detector near air conditioning outlets,

heat sources, or animals.

Bosch Security Systems B.V.

www.boschsecurity.com