Bosch 8-Dec User Manual

Page 323

Advertising
background image

LSN Peripherals | LSN Motion PIR/Microwave | 315

The installation bracket (optional) can be used to swivel the
detector around by +/-45° and to tilt it by +10°/-15° (not
VdS compliant!).

Note

Do not remove the circuit board in the
detector. Risk of damage!

Installation height

Y

Range y: central long-range zone

X

Range x: lateral long-range zone

Wide-angle version

Greatest possible monitoring density by closely-spaced

chessboard-type mirror with 16 zones and a 15 m range.

In the case of perpendicular (standard) installation, the

inclination of the central long-range zone is 5.5°, the

range is 15 m, and the lateral long-range zone is 12 m.

In the case of installation with a 3° incline, the lateral

long-range zone is inclined to 8.5°, the range 13 m, and

the lateral long-range zone is 11 m. This means the zone

configuration can be adjusted to match the spatial

conditions.

Side view

Plan view

X: range of the lateral long-range zone
Y: range of the central long-range zone

Long-range version with IRS 162 (optional)

Long-range version by changing the IRS 162 long-range

mirror (optional)

11 zones give a closed, long-range detection zone of up

to 25 m

Monitoring area cannot be bypassed due to overlapping

operating zone distribution

1

Non-monitored surface

1

Installation height

2

Side view

3

Top view

4

The distance from the side to the wall depends on the range

www.boschsecurity.com

Bosch Security Systems B.V.

6