Bosch 8-Dec User Manual

Page 183

Advertising
background image

Detectors and Accessories | Motion PIR/Microwave | 175

Region

Certification

Russia

GOST

ISM-BLD1-P-F1: IEC 60839-1-3-2001,
IEC 60839-2-2-2001, IEC
60839-2-6-2001, GOST 26342-84,
GOST 27990-88
ISM-BLD1-P-F1: GOST 12997-84, GOST
R 50009-2000, GOST R 51317.3.2-99,
GOST R 51317.3.3-99, GOST R MEK
60065-2002

USA

UL

ANSR: Intrusion Detection Units (UL639),
ANSR7: Intrusion Detection Units Certified
for Canada (cULus)

FCC

ISM-BLD1-P-F1: ESVD1

Italy

IMQ

Canada

IC

ISM-BLD1-P-F1: 1249A-ISMBLD1

Czech
Republic

NBU

SIM-BLD1-P-F1: T1209/2004

France

AFNOR

ISM-BLD1-P-F3: NF, A2P (282111-00)

Sweden

INTYG

ISM-BLD1-P-F1 only: Nr05-270

Brazil

ANATEL

ISM-BLD1-P-F1: 0251-06-1855

Australia

C-tick

F1 model only

Ukraine

IEC 60839‑1‑3‑2001,

IEC 60839‑2‑2‑2001,

IEC 60839‑2‑6‑2001, GOST 26342‑84,

GOST 27990‑88

Europe

Complies with EN50131-2-4 Grade 2

Installation/Configuration Notes

Application Information
Coverage Patterns

Note

An alarm occurs only when an intruder is
detected in areas in which the PIR and
microwave patterns overlap.

Top View Broad: 11 m x 11 m (35 ft x 35 ft)
1 Microwave coverage area

2

PIR coverage pattern

Side View Broad: 11 m x 11 m (35 ft x 35 ft)
1 Microwave coverage area

2

PIR coverage pattern

3 Look-down zone

Mounting
The recommended mounting height is 2.3 m to 2.7 m (7.5 ft
to 9 ft).
The detector can be mounted:

On a flat wall (surface, semi-flush) with the optional

B335 Swivel-mount Bracket, or with the optional B328

Gimbal-mount Bracket,

In the junction of two perpendicular walls, or

On the ceiling with the optional B338 Ceiling-mount

Bracket.

Standby Power
This detector has no internal standby battery. For UL Listed
product installations, 4 hr (60 mAh) of standby power must
be supplied by the control unit or by a UL Listed burglary
power supply.

Parts Included

Quant.

Component

1

Detector

1

Hardware pack

1

Literature pack

Technical Specifications

Environmental Considerations

Complies with EN50131-2-4 Environmental Class II, Security Grade 2
Relative Humidity:

0 to 85%, non-condensing

Temperature (operating):

-29°C to +49°C (-20°F to +120°F)

For UL Listed product installations,

0°C to +49°C (+32°F to +120°F)

Mechanical Properties

Color:

White

Dimensions:

13.2 cm x 6.1 cm x 4.8 cm (5.2 in. x 2.4 in. x 1.9 in.)

Material:

High-impact ABS plastic

Radio Frequency

Interference (RFI)

Immunity:

No alarm or setup on critical frequencies in the range

from 26 MHz to 950 MHz at field strengths less than

50 V/m.

www.boschsecurity.com

Bosch Security Systems B.V.

5