Bosch 8-Dec User Manual

Page 220

Advertising
background image

212 | Detectors and Accessories | Request-to-Exit

Side View
A side view of the DS150i and DS151i coverage pattern.

Technical Specifications

Electrical

Current Draw:

26 mA at 12 VDC

Voltage:

12 VAC or VDC; 24 VAC or VDC

Mechanical

Alarm Output:

Two Form C relay contacts

Indicators:

One activation LED

Relay Latch Time:

Adjustable to 60 sec

Enclosure Dimen-

sions:

3.8 cm x 15.9 cm x 3.8 cm (1.5 in. x 6.25 in. x 1.5 in.)

Enclosure Material: High impact ABS plastic enclosure
Power Loss Default

Mode:

Programmable fail-safe or fail-secure modes.

Timer Mode:

Programmable reset (accumulative) or non-reset

(counting) mode.

Mounting Location: Surface mount on wall or ceiling

Environmental

Operating Tempera-

ture:

-29°C to +49°C (-20°F to +120°F)

Radio Frequency In-

terference (RFI) Im-

munity:

No alarm or setup on critical frequencies in the range

from 26 MHz to 1000 MHz at 50 V/m.

Ordering Information

DS150i Request‑to‑exit PIR Detector

Gray enclosure. For use in request-to-exit

(REX) applications. Provides 2.4 m x 3 m

(8 ft x 10 ft) coverage.

DS150i

DS151i Request‑to‑exit PIR Detector

Black enclosure. For use in request-to-exit

(REX) applications. Provides 2.4 m x 3 m

(8 ft x 10 ft) coverage.

DS151i

Accessories

TP160 Trim Plate

A light gray trim plate used when mounting the

detector over a standard single-gang box.

TP160

TP161 Trim Plate

A black trim plate used when mounting the

sensor over a standard single-gang box.

TP161

Bosch Security Systems B.V.

www.boschsecurity.com

5

Advertising