Msa-lz surface-mount magnetic contact – Bosch 8-Dec User Manual

Page 290

Advertising
background image

282 | Detectors and Accessories | Magnetic Contacts Surface Mount

MSA-LZ Surface-Mount

Magnetic Contact

Features

Conventional surface-mount magnetic contact
VdS class B
Parallel or head-on surface mounting
Conventional perimeter protection

Conventional magnetic contacts are used for opening
surveillance of windows and doors.

Certifications and Approvals

Region

Certification

Europe

CE

MSA-LZ

Germany

VdS

G 191568, B MS/MSA-LZ

Installation/Configuration Notes

Installation notes

Installation can be parallel or head-on.

The AG 4 surface mounting housing makes it possible

to install on ferromagnetic materials.

1

Contact

2

Magnet

3

Offset in the axial direction

Parts Included

Type

Quant. Component

MSA-LZ

1

Surface-mount magnetic contact incl. 6 m

cable and AG4 surface mounting housing

with accessories

Technical Specifications

Type of installation

Surface mount, parallel or head-on

Contact

Normally open contact

Permissible contact load

≤ 5 Watt

Switching current

10 A to 100 mA

Switching voltage max.

≤ 110 V_

Switch tolerance

≥ 10

7

Magnet

AlNiCo 500

Switch dimensions

43 x 12 x 12 mm

Magnet dimensions

Ø 8 mm x 30 mm

Parallel installation distance

≤ 15 mm

Temperature range

-25 °C to 70 °C

Connection cable

6 m, LiYY 4 x 0.14 mm

Protection category

IP68

Bosch Security Systems B.V.

www.boschsecurity.com

5

Advertising